| Problem |
Cause |
Correction |
| No LEDs are illuminated on the display panel. |
- The power cord is not plugged in.
- The power cord is plugged into an outlet controlled by a switch.
|
|
| Water shortage light on the display. |
|
|
| Water leak light on the display panel. |
- Water has been detected inside the bottom of the cabinet.
|
|
| Lights flashing on display panel and beeper sounding. |
- System has gone into fail-safe mode after 1 hour of continuous booster pump operation.
|
|
| Water leaking from quick connect fittings for supply, product and/or drain. |
- Tubing not inserted all the way into fittings.
|
|
| Water spewing from the product water faucet base. |
- The drain tubing is connected to the product water faucet’s air gap, which is not able to handle the flow.
|
|
| Chlorine taste and/or odor in the RO product water. |
|
|
| Other Taste and/or odor. |
- Post filter expended.
- Ro membrane cartridge expended.
- Contamination of the system.
|
|
| System makes product water too slowly. |
- The water supply to the Ro system is not within specifications.
- Prefilter or RO membrane cartridges plugged with sediment or fouled.
|
Precondition the water supply as needed to conform before doing maintenance on the RO system.
Replace the prefilter cartridge. If the rate does not increase, replace the postfilter cartridge and RO membrane cartridge.
|
| High total dissolved solids (TDS) in product water. |
- Water supply to the RO system is not within specifications.
- RO membrane cartridge expended.
|
Precondition the water supply as needed to conform before doing maintenance on the RO system.
Replace the prefilter, postfilter and RO membrane cartridges.
|
Water leaking from airgap opening. |
- The drain side of airgap tubing plugged, restricted, or incorrectly connected to drain point.
|
|