Problem |
Cause |
Correction |
No LEDs are illuminated on the display panel. |
- The power cord is not plugged in.
- The power cord is plugged into an outlet controlled by a switch.
|
|
Water shortage light on the display. |
|
|
Water leak light on the display panel. |
- Water has been detected inside the bottom of the cabinet.
|
-
If water was spilled inside the cabinet during filter cartridge replacement, dry up the spilled water. Otherwise, locate and correct the leak.
-
Visit our Water Leak Warning Light (eflow) article for more information.
|
Lights flashing on display panel and beeper sounding. |
- System has gone into fail-safe mode after 1 hour of continuous booster pump operation.
|
-
If flushing the system, clear the fail-safe mode. Otherwise, determine the reason for continuous pump operation before proceeding.
-
Visit our Flushing the System (eflow) knowledge article for more information.
|
Water leaking from quick connect fittings for supply, product and/or drain. |
- Tubing not inserted all the way into fittings.
|
|
Water spewing from the product water faucet base. |
- The drain tubing is connected to the product water faucet’s air gap, which is not able to handle the flow.
|
|
Chlorine taste and/or odor in the RO product water. |
|
|
Other Taste and/or odor. |
- Post filter expended.
- Ro membrane cartridge expended.
- Contamination of the system.
|
|
System makes product water too slowly. |
- The water supply to the Ro system is not within specifications.
- Prefilter or RO membrane cartridges plugged with sediment or fouled.
|
-
Precondition the water supply as needed to conform before doing maintenance on the RO system.
-
Replace the prefilter cartridge. If the rate does not increase, replace the postfilter cartridge and RO membrane cartridge.
|
High total dissolved solids (TDS) in product water. |
- Water supply to the RO system is not within specifications.
- RO membrane cartridge expended.
|
-
Precondition the water supply as needed to conform before doing maintenance on the RO system.
-
Replace the prefilter, postfilter and RO membrane cartridges.
|
Water leaking from airgap opening.
|
- The drain side of airgap tubing plugged, restricted, or incorrectly connected to drain point.
|
|